Job Timeline (Ref 1409-1670)
Remote Returned to Customer
A Timeline of this job can be seen below.
Arrived - 15-Dec-2015
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 23-Dec-2015
Gazco Mertik Maxitrol Remote Repair Details
Manufacturer : Gazco
Model : Mertik Maxitrol
Customers Fault Description : The receiving unit which powers the gas valve ( On/Off/up/down )has stopped responding to the remote controller ) New batteries in both controller and receiver
This Gazco remote and receiver arrived safely. Initial testing revealed that the handset was transmitting fine yet the receiver was showing no signs of receiving a signal.
When opening the receiver a couple of the battery terminals showed signs of a battery leakage (crystals had formed over the contacts and signs of corrosion were showing)
The fault itself was caused by dry joint on the main board on the power cable (probably caused by the battery terminal leakage), this was resoldered, the leakage cleaned up and full functionality was restored.