Job Timeline (Ref 1842-2161)
Remote Returned to Customer
A Timeline of this job can be seen below.
Arrived - 13-Oct-2016
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 19-Oct-2016
Powertouch Remote Repair Details
Manufacturer : Powertouch
Customers Fault Description : Wiring not connected to the circuit board
This Handset arrived safely and on adding a power source was found to be non functioning. On opening the device there was 2 large solder joint on the battery terminals, there were poorley soldered and not making a proper connection, it was also noticed that the terminals were the wrong way round (i.e. the positive was soldered to the negative and vice versa)
A new battery clip was fitted and soldered correctly, full functionality was restored.