Job Timeline (Ref 2234-2593)
Remote Returned to Customer
A Timeline of this job can be seen below.
Arrived - 06-Apr-2017
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 07-Apr-2017
PURLELINE ENDURO EM4444 Remote Repair Details
Manufacturer : PURLELINE ENDURO
Model : EM4444
Customers Fault Description : NOT WORKING AT ALL WONT TURN ON UNIT INSIDE CARAVAN WORKING OK
This Caravan mover controller arrived safely and on testing did illuminate when batteries were added but there was no response from the power button nor was their a rf signal.
This was due to a common issue whereby moisture damage causes an open circuit on the print, the print was reworked and full functionality was restored.
Remote Images