GTech brake roller tester Remote Repair Details

Manufacturer : GTech

Model : brake roller tester

Customers Fault Description : IR signal not being sent from any of the 3 ir led's: battery shows 9v no obvious damage: buttons buttons sending 4.95v through circuits, continuity tests for live and earth at various poimts on the board prove positive

 

This GTech brake tester remote arrived safely and on testing was confirmed to not be sending out a infrared signal on any button press.

A component test was carried out and the culprit was found to be the 40khz crystal oscillator.  A replacement was fitted and full functionality was restored.

 

 Remote Images

gtech brake tester control repair

back of handset