Job Timeline (Ref 2279-2640)
Remote Returned to Customer
A Timeline of this job can be seen below.
Arrived - 04-May-2017
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 06-May-2017
Triton Remote Repair Details
Manufacturer : Triton
Customers Fault Description : Switching off button not working Adjusting temperature button not working
This Body dryer control arrived safely and on inspection was found to have badly damaged facia around the buttons. The front had to be peeled off and this led to a rip in the front vinyl emanating from one of the damaged buttons (see video). The Main fault was due to water damage on the PCB causing corrosion, there were in total 4 breaks in the print which led to both of the top buttons being faulty.
The print was reworked and full functionality was restored. Please note that the facias are not available as a spare and cannot be replaced, the facia was repaired and a protective cover was placed over it to give a bit of protection against further water damage but this control is not full waterproof therefore please take care.
Remote Image